| Date | Who | Change Made |
|---|---|---|
| 4/22/2020 | Unplugged Sno Falls Golf Course receiver; Fish Hatchery Rd sensor now using Tall Chief receiver | |
| 03/23/2020 | Andy Obst | Replaced 14' Goose & Gander sensor/transmitter with 30' sensor (30' sensor mounted in bracket is 3.3" lower than the 14' sensor - made changes in Admin page) |
| 05/20/20 | Andy Obst | G&G, Sno Falls GC, Wild Canary, and 124th at Local Roots marked as "Offline" due to bad readings from vegetation interference. |
| 05/20/20 | Andy Obst | Keller Dairy Gage taken down for troubleshooting - had been offline for weeks. Offline because transmitter was found to be wet inside. Let transmitter dry out before redeploying. |
| 06/01/20 | Andy Obst | The "T" marked as "Offline" due to bad readings. |
| 06/17/20 | Andy Obst | Correcting measurement information from 03/23/20 for G&G sensor/transmitter. The 30' sensor is 1" lower than the 14' sensor that was originally there. Changed the "sensor height" in Floodzilla from 108.34' to 107.34' to account for the 1" difference between the two sensors. Check to be sure this was changed from the original measurement. I'm pretty sure on 03/23 I changed the sensor height back to the original when I realized the 3.3" measurement was incorrect. |
| 09/08/20 | Lisa Kysar | Outdoor receiver inside at Tall Chief. 2 indoor receivers facing out both the kitchen window (South) and the SVPA office window (North). South receiver has been installed in window. One extra indoor receiver is in test kit. 30' Sensor 01-5A-48 installed on Stossel Bridge across from USGS Carnation gage. Stossel gage configured online. Batteries changed at all sites except Sno Falls GC. |
| 09/09/20 | Lisa Kysar | Installed 01-5d-5f on Tolt bridge; Installed 01-5d-5b at 124th W; installed indoor receiver in South-facing kitchen window of SVPA building. |
| 11/14/2022 | Regina Fletcher | Replaced 14' sensor on device (0135D3) at the "T" with a 30' sensor from office. Changed sensor height on Floodzilla from 110.5' to 110.4' based on sensor length distance. Changed Linear Scale remotely through liquidlevels.com. |
| 1/25/2023 | Regina Fletcher | Replaced 30' sensor on device (0135D3) at the "T" with a brand new 14' sensor. Changed sensor height on Floodzilla from 110.4' to 110.5' based on sensor length distance. Changed Linear Scale remotely through liquidlevels.com. |