SVPA-17

From floodzilla-wiki
Revision as of 23:23, 23 May 2020 by GearyEppley (talk | contribs)
Jump to navigation Jump to search

SVPA-17: NE 100th St at Goose & Gander Farm

Status ACTIVE
Downstream USGS-22 Carnation
Upstream SVPA-15 124th East

Attributes

  • Road - NE 100th St
  • Est. 2019
  • Farm field
  • Dry when not flooding
  • Mounted on 4x4 post

Installation Notes

Problems and Considerations: (May 2020)

  • Sensor Height – mount at least 12.69’ above concrete pad.
    • Cantilever arm must be level and static.
    • This site could use a 14’ sensor if it is repaired.
  • Access issues – location is immediately adjacent to farm access road, but may not be useable to access.  
    • Will need ladder or some way to access transmitter for battery changes, maintenance.
  • Sensing Cone Issues – the cone of detection will be wider since the sensor will be higher than is currently.
    • Sensor should be mounted out (> 21”) away from post (radius of cone).