'''Flood Sensor/Transmitter Installation Upgrades'''  
+
<u>'''Gage Installations - Location Specifications and Considerations for Upgrades'''</u>
 
<br />
 
<br />
{| class="wikitable"
 
|Sensor
 
  
''Either 14’ or 30’ range''
+
'''FOR EACH LOCATION KEEP IN MIND:'''
|}
 
{| class="wikitable"
 
|Sensor Cable (6’)
 
  
''Can order longer cables if needed''
+
'''Accessibility'''
|}
 
{| class="wikitable"
 
|Transmitter Box
 
|}
 
{| class="wikitable"
 
|Mounting Bracket
 
  
''Sensor and transmitter can be    removed from this and mounted separately''
+
* Ease of access to transmitter box to change batteries or remove for troubleshooting or repair.
|}                             
 
Figure 1. Senix Sensor and Transmitter with Mounting Bracket
 
  
The following listed sensor/transmitter installations need to be revamped keeping in mind:
+
'''Theft and Tampering'''
  
·        Accessibility
+
* This hasn’t been a significant problem, but something to keep in mind.
  
o  Ease of access to transmitter box to change batteries or remove for troubleshooting or repair.
+
'''Data Reliability'''
  
·        Theft and Tampering
+
* Sensor must be at same exact height in exact same position each time it is raised and lowered.
  
o  This hasn’t been a significant problem, but something to keep in mind.
+
* Sensor must be perpendicular to ground.
  
·        Data Reliability
+
* If on a cantilevered arm that raises and lowers, the arm must be level and static when raised.
  
o  Sensor must be at same exact height in exact same position each time it is raised and lowered.
+
'''Flood Height'''
  
o  Sensor must be perpendicular to ground.
+
* Sensors must be mounted above 60’ flood level.
  
o  If on a cantilevered arm that raises and lowers, the arm must be level and static when raised.
+
* The USGS Carnation gage recorded 60’ flood was ~4.5’ higher than the Oct 22, 2019 flood.
  
·        Flood Height
+
* See '''Table 1.''' for sensor mounting height requirements.
 
 
o  Sensors must be mounted above 60’ flood level.
 
 
 
o  The USGS Carnation gage recorded 60’ flood was ~4.5’ higher than the Oct 22, 2019 flood.
 
 
 
o  See '''Table 1.''' for sensor mounting height requirements.
 
  
 
Table 1. Sensor Height Requirements for Maximum Flood Levels
 
Table 1. Sensor Height Requirements for Maximum Flood Levels
 
{| class="wikitable"
 
{| class="wikitable"
|'''Site'''
+
|'''Gage Location'''
 
|'''Current Sensor Height (ft ASL)'''
 
|'''Current Sensor Height (ft ASL)'''
 
|'''Oct 22nd Flood Crest (ft ASL)'''
 
|'''Oct 22nd Flood Crest (ft ASL)'''
|'''Estimated 60' Flood Crest (ft  ASL)'''  
+
|'''Estimated 60' Flood Crest (ft  ASL)'''
 
|'''Distance of 60' Flood from  Sensor (ft)'''
 
|'''Distance of 60' Flood from  Sensor (ft)'''
 
|'''Current Sensor Height (ft above  ground)'''
 
|'''Current Sensor Height (ft above  ground)'''
 
|'''New Sensor Height Requirements  (ft above ground)'''
 
|'''New Sensor Height Requirements  (ft above ground)'''
 
|-
 
|-
|Sno Falls Golf Course
+
|SE Fish Hatchery Road at Snoqualmie Falls Golf Course
 
|99.06
 
|99.06
|unk
+
|unknown - not running during flood
 
|
 
|
 
|
 
|
Line 65: Line 46:
 
|>11.31
 
|>11.31
 
|-
 
|-
|The "T"
+
|W Snoqualmie River Rd SE at the “T”
 
|81.69
 
|81.69
 
|80.47
 
|80.47
Line 73: Line 54:
 
|12.48
 
|12.48
 
|-
 
|-
|Keller Dairy
+
|Snoqualmie River at Keller Dairy
 
|90.68
 
|90.68
 
|85.84
 
|85.84
Line 81: Line 62:
 
|20
 
|20
 
|-
 
|-
|Blue Heron Golf Course
+
|W Snoqualmie River Rd NE at the Blue Heron Golf Course
 
|74.32
 
|74.32
|73.46
+
|73.46 (max pre-crest, sensor taken down due to flood levels approaching sensor)
 
|77.96
 
|77.96
 
|<nowiki>-3.64</nowiki>
 
|<nowiki>-3.64</nowiki>
 
|11.3
 
|11.3
|15.8
+
|>15.8
 
|-
 
|-
|Tolt Bridge
+
|Snoqualmie River at the Tolt Bridge
|Not installed
+
|not installed
 
|unknown
 
|unknown
 
|unknown
 
|unknown
|
+
|n/a
|
+
|n/a
|Bridge Guard Rail Adequate
+
|height of bridge guard rail adequate
 
|-
 
|-
|Stossel Bridge
+
|Snoqualmie River at Stossel Bridge
|Not installed
+
|not installed
 
|57.96
 
|57.96
 
|62.46
 
|62.46
|
+
|n/a
|
+
|n/a
|Bridge Guard Rail Adequate
+
|height of bridge guard rail adequate
 
|-
 
|-
|Goose and Gander
+
|NE 100<sup>th</sup> St at Goose and Gander Farm
 
|54.24
 
|54.24
 
|53.81
 
|53.81
Line 113: Line 94:
 
|12.69
 
|12.69
 
|-
 
|-
|124th East at Local Roots
+
|24<sup>th</sup> St East at Local Roots Farm
 
|55.45
 
|55.45
 
|46.96
 
|46.96
Line 121: Line 102:
 
|15.04
 
|15.04
 
|-
 
|-
|124th West
+
|124<sup>th</sup> St West
|Not installed
+
|not installed
|
+
|estimate based on photos and 124th E
|
+
|unknown
|
+
|n/a
|
+
|n/a
 
|TBD
 
|TBD
 
|-
 
|-
|Wild Canary Farm
+
|NE 138<sup>th</sup> St at Wild Canary Farm
 
|47.9
 
|47.9
 
|45.26
 
|45.26
Line 138: Line 119:
 
|}
 
|}
  
 +
'''Antennas'''
  
·        Antennas
+
* Must be mounted directly on transmitter box and cannot be extended.
 
 
o  Must be mounted directly on transmitter box and cannot be extended.
 
 
 
·        Transmitters
 
 
 
o  Mount transmitter as high as possible to improve line of sight and RSSI.
 
 
 
o  Must be easily accessible from the ground or using a short ladder.
 
 
 
o  Can be mounted separate from sensor.
 
 
 
o  Cannot become submerged during flooding.
 
 
 
·        Sensors
 
  
o  Can be mounted separate from transmitter.
+
'''Transmitters'''
  
o  Cannot be mounted higher than the range of sensor (30’ sensor: 30’, 14’ sensor: 14’)
+
* Mount transmitter as high as possible to improve line of sight and RSSI.
 +
* Must be easily accessible from the ground or using a short ladder.
 +
* Can be mounted separate from sensor.
 +
* Cannot become submerged during flooding.
  
o  Come with 6’ cable - can be cut.
+
'''Sensors'''
  
o  Can be ordered with longer cables (15 – 200 ft).
+
* Can be mounted separate from transmitter.
 +
* Cannot be mounted higher than the range of sensor (30’ sensor: 30’, 14’ sensor: 14’)
 +
* Come with 6’ cable - can be cut.
 +
* Can be ordered with longer cables (15 – 200').
 +
* Will not give accurate readings if flood waters are within 10” of the sensor face.
 +
* Can be submerged during flooding BUT, will not give accurate readings.
 +
* Must be mounted directly over center of ditch/concrete pad.
  
o  Will not give accurate readings if flood waters are within 10” of the sensor face.
+
'''Sensor Cone'''
  
o  Can be submerged during flooding BUT, will not give accurate readings.
+
* Emits an ultrasonic pulse with a 15° sensing cone.
 
+
* The higher the sensor, the larger the diameter of the sensing cone at the ground/water surface.
o  Must be mounted directly over center of ditch/concrete pad.
+
* Be sure the sensor is extended far enough from the mounting pole to not sense it.
 
+
* See '''Table 2.''' For cone diameters
·        Sensor Cone
 
 
 
o  Emits an ultrasonic pulse with a 15° sensing cone.
 
 
 
o  The higher the sensor, the larger the diameter of the sensing cone at the ground/water surface.
 
 
 
o  Be sure the sensor is extended far enough from the mounting pole to not sense it.
 
 
 
o  See '''Table 2.''' For cone diameters
 
  
 
Table 2. Ultrasonic Cone Diameters at Varying Heights
 
Table 2. Ultrasonic Cone Diameters at Varying Heights
Line 307: Line 275:
  
  
 +
'''GAGE LOCATIONS:'''
  
'''1. W Snoqualmie River Rd NE at the Blue Heron Golf Course'''  
+
'''1. W Snoqualmie River Rd NE at the Blue Heron Golf Course'''
  
'''Problems and Considerations:'''  
+
'''Problems and Considerations:'''
  
·        Sensor Height – mount > 15.8 ft above surface water in ditch, and directly over center.
+
* Sensor Height – mount > 15.8' above surface water in ditch.
 +
** Cantilever arm must be level and static.
 +
** Mount over center of ditch.
 +
** Could use tree behind existing post to get sensor up higher.
 +
* RSSI issues – mount antenna higher for better RSSI, site is furthest away from receiver, has connection problems.
 +
* Access issues – required height of sensor and position of ditch makes access difficult with a ladder.
 +
** Must be able to access transmitter on foot, or using a short ladder.
  
·        RSSI issues – mount antenna higher for better RSSI, furthest away from receiver, has connection problems.
 
 
·        Access issues – required height of sensor and position of ditch makes access difficult with a ladder.
 
 
·        Could use tree behind existing post to get sensor up higher. 
 
  
 
'''2. 124<sup>th</sup> St East at Local Roots Farm'''
 
'''2. 124<sup>th</sup> St East at Local Roots Farm'''
  
'''Problems and Considerations:'''  
+
'''Problems and Considerations:'''
 
 
·        Sensor Height – mount at same height or greater (15.04’).
 
 
 
o   Cantilever arm must be level and static.
 
 
 
o   Mount out over center of ditch if possible.
 
  
·        RSSI issues must be kept at same height for best RSSI.
+
* Sensor Height mount at same height or greater (15.04’).
 +
** Cantilever arm must be level and static.
 +
** Mount out over center of ditch if possible.
  
·        Access issues – field adjacent to ditch is often saturated, access to site by foot.  
+
* RSSI issues – must be kept at same height for best RSSI.
 +
* Access issues – field adjacent to ditch is often saturated, access to site by foot.
 +
** Cannot reach transmitter to change batteries without taking the post down, shouldn't have to take post down to access transmitter.
 +
** Position of post adjacent to the ditch is awkward and unsafe when using a ladder to try and access sensor.
 +
** Could move the location closer to 124<sup>th</sup> St for better vehicle access.
  
o   Cannot reach transmitter to change batteries without taking the post down, because of its position in the ditch. 
+
* Sensing Cone Issues – the cone of detection is very wide at the ground level.
 +
** Be sure sensor mounted out from the post by at least 24” (radius of cone at ground level).
 +
** Problems with flood debris getting caught on post and being detected within the cone even after flood waters recede.
  
o   Could move the location closer to 124<sup>th</sup> St for better vehicle access.
 
 
·        Sensing Cone Issues – the cone of detection is very wide at the ground level.
 
 
o   Be sure sensor mounted out from the post by at least 24” (radius of cone at ground level).
 
  
 
'''3. NE 138<sup>th</sup> St at Wild Canary Farm'''
 
'''3. NE 138<sup>th</sup> St at Wild Canary Farm'''
  
'''Problems and Considerations:'''  
+
'''Problems and Considerations:'''
  
·        Sensor Height – mount at least 14.5’ above bottom of ditch (must be > 2’ higher than current)
+
* Sensor Height – mount at least 14.5’ above bottom of ditch (must be > 2’ higher than current)
 +
** Mount out over center of ditch.
 +
** Cantilever arm must be level and static.
 +
** Sensor should be moved from NNW to more of a NW orientation to be directly over the ditch to get the best possible readings.
  
o   Mount out over center of ditch.  
+
* RSSI issues – poor RSSI since this location is farthest from receiver and is in a topographic hole.
 +
** Mount transmitter and antenna as high as possible (use existing telephone pole?)
 +
** Mount transmitter and sensor separately.
 +
** Use 30’ sensor with longer cable.  
  
o   Cantilever arm must be level and static.  
+
* Access issues – location is immediately adjacent to gravel road, but height poses problem.
 +
** If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.  
  
o   Sensor should be moved from NNW to more of a NW orientation to be directly over the ditch to get the best possible readings.  
+
* Sensing Cone Issues – the cone of detection is very wide at the ground level.
 +
** Sensor should be mounted at minimum height requirements to minimize size of cone.
 +
** Vegetation will need to be cut back extensively along ditch edges.
 +
** Sensing cone least 44.23” (diameter of cone at ground level).
  
·        RSSI issues – poor RSSI since this location is farthest from receiver and is in a topographic hole.
 
 
o   Mount transmitter and antenna as high as possible (use existing telephone pole?)
 
 
o  Mount transmitter and sensor separately.
 
 
o   Use 30’ sensor with longer cable.
 
 
·        Access issues – location is immediately adjacent to gravel road, but height poses problem.
 
 
o   If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
 
 
·        Sensing Cone Issues – the cone of detection is very wide at the ground level.
 
 
o   Sensor should be mounted at minimum height requirements to minimize size of cone.
 
 
o   Vegetation will need to be cut back extensively along ditch edges.
 
 
o   Sensing cone least 44.23” (diameter of cone at ground level).
 
  
 
'''4. W Snoqualmie River Rd SE at the “T”'''
 
'''4. W Snoqualmie River Rd SE at the “T”'''
 
  
 
'''Problems and Considerations:'''
 
'''Problems and Considerations:'''
  
·        Sensor Height – mount at 12.48’ above bottom of ditch.  
+
* Sensor Height – mount at 12.48’ above bottom of ditch.
 +
** Currently the only site using a 14’ sensor – do not mount higher than 14’.  
  
o   Currently the only site using a 14’ sensor do not mount higher than 14’.
+
* Access issues location is immediately adjacent to road but will be raised up higher.
 +
** This is the lowest part of the road, so it should be installed in the same location.
 +
** Theft worries?
  
·        Access issues – location is immediately adjacent to road but will be raised up higher.
+
* Sensing Cone Issues – the cone of detection will be wider with the new height.
 
+
* Be sure sensor mounted out from the post by at least 20.5” (radius of cone at ground level).
o   This is the lowest part of the road, so it should be installed in the same location.
+
* Be sure road edge is not within cone.
 
+
* May need to install post back from ditch.
o   Theft worries?
 
 
 
·        Sensing Cone Issues – the cone of detection will be wider with the new height.
 
 
 
o   Be sure sensor mounted out from the post by at least 20.5” (radius of cone at ground level).
 
 
 
o   Be sure road edge is not within cone.
 
 
 
o   May need to install post back from ditch
 
  
  
Line 402: Line 353:
 
'''Problems and Considerations:'''
 
'''Problems and Considerations:'''
  
·        Sensor Height – mount at current height or higher (> 11.31’).
+
* Sensor Height – mount at current height or higher (> 11.31’).
 
+
** Cantilever arm must be level and static.
o  Cantilever arm must be level and static.  
+
** Unsure of 60’ flood height at this location.
 
+
** Currently sensing concrete wall, mount out over edge of concrete pad for best readings.
o  Unsure of 60’ flood height at this location.
 
  
o  Currently sensing concrete wall, mount out over edge of concrete pad for best readings.  
+
* RSSI issues – Removed indoor receiver from this location. poor RSSI since this location is far from receiver.
 +
** Mount transmitter and antenna as high as possible (use existing telephone pole?)
 +
** Mount transmitter and sensor separately.
 +
** Use 30’ sensor with longer cable.
  
·        RSSI issues – Removed indoor receiver from this location. poor RSSI since this location is far from receiver.
+
* Access issues – location is immediately adjacent to parking lot, but height and position over ditch poses problem.
 +
** Transmitter is virtually inaccessible as it is now.  
 +
** If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
 +
** Ladder will not fit in concrete pad below sensor – spread too wide.  
  
o  Mount transmitter and antenna as high as possible (use existing telephone pole?)
+
* Sensing Cone Issues – the cone of detection is very wide at the ground level.
 
+
** Sensor should be mounted at minimum height requirements to minimize size of cone.
o   Mount transmitter and sensor separately.
+
** Vegetation (knotweed) will need to be maintained.
 
+
** Sensing cone least 37.91” (diameter of cone at ground level).
o  Use 30’ sensor with longer cable.
 
 
 
·        Access issues – location is immediately adjacent to parking lot, but height and position over ditch poses problem.
 
 
 
o   Transmitter is virtually inaccessible as it is now.
 
 
 
o  If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
 
 
 
o  Ladder will not fit in concrete pad below sensor – spread too wide.
 
 
 
·        Sensing Cone Issues – the cone of detection is very wide at the ground level.
 
 
 
o  Sensor should be mounted at minimum height requirements to minimize size of cone.
 
 
 
o  Vegetation (knotweed) will need to be maintained.  
 
 
 
o   Sensing cone least 37.91” (diameter of cone at ground level).
 
  
  
 
'''6. Snoqualmie River at Keller Dairy'''  
 
'''6. Snoqualmie River at Keller Dairy'''  
 
  
 
'''Problems and Considerations:'''
 
'''Problems and Considerations:'''
  
·        Sensor Height – mount at current height (20’).
+
* Sensor Height – mount at current height (20’).
 
+
** Cantilever arm must be level and static.
o   Cantilever arm must be level and static.
 
 
 
·        RSSI issues – receiver is nearby, but leaf cover may be blocking line of sight.
 
 
 
o   Could try to get antenna out over river further or up higher.
 
 
 
o  Could mount transmitter and sensor separately.
 
  
·        Safety Issues location has a steep (~10’) drop off into the river.  
+
* RSSI issues receiver is nearby, but leaf cover may be blocking line of sight.
 +
** Could try to get antenna out over river further or up higher.
 +
** Could mount transmitter and sensor separately.  
  
o   Design must take into account river safety and ease of access of transmitter.
+
* Safety Issues – location has a steep (~10’) drop off into the river.
 +
** Design must take into account river safety and ease of access of transmitter.  
  
o   SVPA owns harness and rope if needed for access.
+
* Access issues – location is immediately adjacent to road, but in a precarious spot at edge of bank.
 +
** If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.  
  
·        Access issues location is immediately adjacent to road, but in a precarious spot at edge of bank.  
+
* Sensing Cone Issues the cone of detection is very wide at water surface.
 +
** Any interfering branches may need to be removed.
 +
** Sensor should be mounted out over the river as far as it is now or farther.
  
o   If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
 
 
·        Sensing Cone Issues – the cone of detection is very wide at water surface.
 
 
o  Any interfering branches may need to be removed.
 
 
o   Sensor should be mounted out over the river as far as it is now or farther. 
 
  
 
'''7. NE 100<sup>th</sup> St at Goose and Gander Farm'''   
 
'''7. NE 100<sup>th</sup> St at Goose and Gander Farm'''   
Line 470: Line 400:
 
'''Problems and Considerations:'''
 
'''Problems and Considerations:'''
  
·        Sensor Height – mount at least 12.69’ above concrete pad.
+
* Sensor Height – mount at least 12.69’ above concrete pad.
 
+
** Cantilever arm must be level and static.
o   Cantilever arm must be level and static.  
+
** This site could use a 14’ sensor if it is repaired.
 
 
o   This site could use a 14’ sensor if it is repaired.  
 
  
·        Access issues – location is immediately adjacent to farm access road, but may not be useable to access.  
+
* Access issues – location is immediately adjacent to farm access road, but may not be useable to access.  
 +
** Will need ladder or some way to access transmitter for battery changes, maintenance.
  
o   Will need ladder or some way to access transmitter for battery changes, maintenance.
+
* Sensing Cone Issues – the cone of detection will be wider since the sensor will be higher than is currently.
 +
** Sensor should be mounted out (> 21”) away from post (radius of cone).
  
·        Sensing Cone Issues – the cone of detection will be wider since the sensor will be higher than is currently.
 
 
o   Sensor should be mounted out (> 21”) away from post (radius of cone). 
 
  
 
'''8. 124<sup>th</sup> St West – Location TBD (47.709092, -122.002502)'''
 
'''8. 124<sup>th</sup> St West – Location TBD (47.709092, -122.002502)'''
Line 488: Line 415:
 
'''Considerations:'''
 
'''Considerations:'''
  
·        Needs to be constructed in the KC right of way, over the ditch.
+
* Needs to be constructed in the KC right of way, over the ditch.
 
+
* Find the low spot in the road using survey data for better placement.
·        Find the low spot in the road using survey data for better placement.
+
* Height TBD based on estimated flood height here.
 
+
* Will need a design that is easy to access without a ladder since there is no parking to bring a ladder and it’s right next to a busy street.
·        Height TBD based on estimated flood height here.
 
 
 
·        Will need a design that is easy to access without a ladder since there is no parking to bring a ladder and it’s right next to a busy street.
 
  
  

Revision as of 22:46, 7 May 2020

Gage Installations - Location Specifications and Considerations for Upgrades

FOR EACH LOCATION KEEP IN MIND:

Accessibility

  • Ease of access to transmitter box to change batteries or remove for troubleshooting or repair.

Theft and Tampering

  • This hasn’t been a significant problem, but something to keep in mind.

Data Reliability

  • Sensor must be at same exact height in exact same position each time it is raised and lowered.
  • Sensor must be perpendicular to ground.
  • If on a cantilevered arm that raises and lowers, the arm must be level and static when raised.

Flood Height

  • Sensors must be mounted above 60’ flood level.
  • The USGS Carnation gage recorded 60’ flood was ~4.5’ higher than the Oct 22, 2019 flood.
  • See Table 1. for sensor mounting height requirements.

Table 1. Sensor Height Requirements for Maximum Flood Levels

Gage Location Current Sensor Height (ft ASL) Oct 22nd Flood Crest (ft ASL) Estimated 60' Flood Crest (ft ASL) Distance of 60' Flood from Sensor (ft) Current Sensor Height (ft above ground) New Sensor Height Requirements (ft above ground)
SE Fish Hatchery Road at Snoqualmie Falls Golf Course 99.06 unknown - not running during flood 11.31 >11.31
W Snoqualmie River Rd SE at the “T” 81.69 80.47 84.97 -3.28 7.98 12.48
Snoqualmie River at Keller Dairy 90.68 85.84 90.34 0.34 20 20
W Snoqualmie River Rd NE at the Blue Heron Golf Course 74.32 73.46 (max pre-crest, sensor taken down due to flood levels approaching sensor) 77.96 -3.64 11.3 >15.8
Snoqualmie River at the Tolt Bridge not installed unknown unknown n/a n/a height of bridge guard rail adequate
Snoqualmie River at Stossel Bridge not installed 57.96 62.46 n/a n/a height of bridge guard rail adequate
NE 100th St at Goose and Gander Farm 54.24 53.81 58.31 -4.07 8.19 12.69
24th St East at Local Roots Farm 55.45 46.96 51.46 3.99 15.04 15.04
124th St West not installed estimate based on photos and 124th E unknown n/a n/a TBD
NE 138th St at Wild Canary Farm 47.9 45.26 49.76 -1.86 12.3 14.5

Antennas

  • Must be mounted directly on transmitter box and cannot be extended.

Transmitters

  • Mount transmitter as high as possible to improve line of sight and RSSI.
  • Must be easily accessible from the ground or using a short ladder.
  • Can be mounted separate from sensor.
  • Cannot become submerged during flooding.

Sensors

  • Can be mounted separate from transmitter.
  • Cannot be mounted higher than the range of sensor (30’ sensor: 30’, 14’ sensor: 14’)
  • Come with 6’ cable - can be cut.
  • Can be ordered with longer cables (15 – 200').
  • Will not give accurate readings if flood waters are within 10” of the sensor face.
  • Can be submerged during flooding BUT, will not give accurate readings.
  • Must be mounted directly over center of ditch/concrete pad.

Sensor Cone

  • Emits an ultrasonic pulse with a 15° sensing cone.
  • The higher the sensor, the larger the diameter of the sensing cone at the ground/water surface.
  • Be sure the sensor is extended far enough from the mounting pole to not sense it.
  • See Table 2. For cone diameters

Table 2. Ultrasonic Cone Diameters at Varying Heights

Distance from Sensor (ft) Diameter of Cone (in) Diameter of Cone (ft)
1 3.15 0.26
2 6.32 0.53
3 9.47 0.79
4 12.64 1.05
5 15.79 1.32
6 18.96 1.58
7 22.11 1.84
8 25.27 2.11
9 28.43 2.37
10 31.59 2.63
11 34.75 2.90
12 37.91 3.16
13 41.07 3.42
14 44.23 3.69
15 47.39 3.95
16 50.55 4.21
17 53.71 4.48
18 56.87 4.74
19 60.02 5.00
20 63.18 5.27
21 66.34 5.53
22 69.50 5.79
23 72.66 6.06
24 75.82 6.32
25 78.98 6.58
26 82.14 6.84
27 85.30 7.11
28 88.46 7.37
29 91.62 7.63
30 94.78 7.90


GAGE LOCATIONS:

1. W Snoqualmie River Rd NE at the Blue Heron Golf Course

Problems and Considerations:

  • Sensor Height – mount > 15.8' above surface water in ditch.
    • Cantilever arm must be level and static.
    • Mount over center of ditch.
    • Could use tree behind existing post to get sensor up higher.
  • RSSI issues – mount antenna higher for better RSSI, site is furthest away from receiver, has connection problems.
  • Access issues – required height of sensor and position of ditch makes access difficult with a ladder.
    • Must be able to access transmitter on foot, or using a short ladder.


2. 124th St East at Local Roots Farm

Problems and Considerations:

  • Sensor Height – mount at same height or greater (15.04’).
    • Cantilever arm must be level and static.
    • Mount out over center of ditch if possible.
  • RSSI issues – must be kept at same height for best RSSI.
  • Access issues – field adjacent to ditch is often saturated, access to site by foot.
    • Cannot reach transmitter to change batteries without taking the post down, shouldn't have to take post down to access transmitter.
    • Position of post adjacent to the ditch is awkward and unsafe when using a ladder to try and access sensor.
    • Could move the location closer to 124th St for better vehicle access.
  • Sensing Cone Issues – the cone of detection is very wide at the ground level.
    • Be sure sensor mounted out from the post by at least 24” (radius of cone at ground level).
    • Problems with flood debris getting caught on post and being detected within the cone even after flood waters recede.


3. NE 138th St at Wild Canary Farm

Problems and Considerations:

  • Sensor Height – mount at least 14.5’ above bottom of ditch (must be > 2’ higher than current)
    • Mount out over center of ditch.
    • Cantilever arm must be level and static.
    • Sensor should be moved from NNW to more of a NW orientation to be directly over the ditch to get the best possible readings.
  • RSSI issues – poor RSSI since this location is farthest from receiver and is in a topographic hole.
    • Mount transmitter and antenna as high as possible (use existing telephone pole?)
    • Mount transmitter and sensor separately.
    • Use 30’ sensor with longer cable.
  • Access issues – location is immediately adjacent to gravel road, but height poses problem.
    • If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
  • Sensing Cone Issues – the cone of detection is very wide at the ground level.
    • Sensor should be mounted at minimum height requirements to minimize size of cone.
    • Vegetation will need to be cut back extensively along ditch edges.
    • Sensing cone least 44.23” (diameter of cone at ground level).


4. W Snoqualmie River Rd SE at the “T”

Problems and Considerations:

  • Sensor Height – mount at 12.48’ above bottom of ditch.
    • Currently the only site using a 14’ sensor – do not mount higher than 14’.
  • Access issues – location is immediately adjacent to road but will be raised up higher.
    • This is the lowest part of the road, so it should be installed in the same location.
    • Theft worries?
  • Sensing Cone Issues – the cone of detection will be wider with the new height.
  • Be sure sensor mounted out from the post by at least 20.5” (radius of cone at ground level).
  • Be sure road edge is not within cone.
  • May need to install post back from ditch.


5. SE Fish Hatchery Road at Snoqualmie Falls Golf Course

Problems and Considerations:

  • Sensor Height – mount at current height or higher (> 11.31’).
    • Cantilever arm must be level and static.
    • Unsure of 60’ flood height at this location.
    • Currently sensing concrete wall, mount out over edge of concrete pad for best readings.
  • RSSI issues – Removed indoor receiver from this location. poor RSSI since this location is far from receiver.
    • Mount transmitter and antenna as high as possible (use existing telephone pole?)
    • Mount transmitter and sensor separately.
    • Use 30’ sensor with longer cable.
  • Access issues – location is immediately adjacent to parking lot, but height and position over ditch poses problem.
    • Transmitter is virtually inaccessible as it is now.
    • If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
    • Ladder will not fit in concrete pad below sensor – spread too wide.
  • Sensing Cone Issues – the cone of detection is very wide at the ground level.
    • Sensor should be mounted at minimum height requirements to minimize size of cone.
    • Vegetation (knotweed) will need to be maintained.
    • Sensing cone least 37.91” (diameter of cone at ground level).


6. Snoqualmie River at Keller Dairy

Problems and Considerations:

  • Sensor Height – mount at current height (20’).
    • Cantilever arm must be level and static.
  • RSSI issues – receiver is nearby, but leaf cover may be blocking line of sight.
    • Could try to get antenna out over river further or up higher.
    • Could mount transmitter and sensor separately.
  • Safety Issues – location has a steep (~10’) drop off into the river.
    • Design must take into account river safety and ease of access of transmitter.
  • Access issues – location is immediately adjacent to road, but in a precarious spot at edge of bank.
    • If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
  • Sensing Cone Issues – the cone of detection is very wide at water surface.
    • Any interfering branches may need to be removed.
    • Sensor should be mounted out over the river as far as it is now or farther.


7. NE 100th St at Goose and Gander Farm

Problems and Considerations:

  • Sensor Height – mount at least 12.69’ above concrete pad.
    • Cantilever arm must be level and static.
    • This site could use a 14’ sensor if it is repaired.
  • Access issues – location is immediately adjacent to farm access road, but may not be useable to access.  
    • Will need ladder or some way to access transmitter for battery changes, maintenance.
  • Sensing Cone Issues – the cone of detection will be wider since the sensor will be higher than is currently.
    • Sensor should be mounted out (> 21”) away from post (radius of cone).


8. 124th St West – Location TBD (47.709092, -122.002502)

Considerations:

  • Needs to be constructed in the KC right of way, over the ditch.
  • Find the low spot in the road using survey data for better placement.
  • Height TBD based on estimated flood height here.
  • Will need a design that is easy to access without a ladder since there is no parking to bring a ladder and it’s right next to a busy street.


BRIDGE INSTALLS

9. Stossel Bridge


10. Tolt Bridge