SVPA-12: NE 138th St at Wild Canary Farm

Status ACTIVE
Upstream SVPA-15W 124th West
Downstream USGS-9 Duvall

Attributes

  • Est. 2019
  • Road - NE 138th St
  • Ditch
  • Dry when not flooding
  • Mounted on utility pole

Installation Notes

Problems and Considerations (May 2020)

  • Sensor Height – mount at least 14.5’ above bottom of ditch (must be > 2’ higher than current)
    • Mount out over center of ditch.
    • Cantilever arm must be level and static.
    • Sensor should be moved from NNW to more of a NW orientation to be directly over the ditch to get the best possible readings.
  • RSSI issues – poor RSSI since this location is farthest from receiver and is in a topographic hole.
    • Mount transmitter and antenna as high as possible (use existing telephone pole?)
    • Mount transmitter and sensor separately.
    • Use 30’ sensor with longer cable.
  • Access issues – location is immediately adjacent to gravel road, but height poses problem.
    • If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
  • Sensing Cone Issues – the cone of detection is very wide at the ground level.
    • Sensor should be mounted at minimum height requirements to minimize size of cone.
    • Vegetation will need to be cut back extensively along ditch edges.
    • Sensing cone least 44.23” (diameter of cone at ground level).