Difference between revisions of "SVPA-26"

From floodzilla-wiki
Jump to navigation Jump to search
Line 4: Line 4:
 
| ACTIVE
 
| ACTIVE
 
|-
 
|-
! scope="row"| Downstream
+
! scope="row"| Upstream
 
| [[SVPA-33|SVPA-33 Keller Dairy]]
 
| [[SVPA-33|SVPA-33 Keller Dairy]]
 
|-
 
|-
! scope="row"| Upstream
+
! scope="row"| Downstream
 
| [[USGS-22|USGS-22 Carnation]]
 
| [[USGS-22|USGS-22 Carnation]]
 
|}  
 
|}  

Revision as of 23:27, 23 May 2020

SVPA-26: W Snoqualmie River Rd NE at Blue Heron Golf Course

Status ACTIVE
Upstream SVPA-33 Keller Dairy
Downstream USGS-22 Carnation

Attributes

  • Est. 2019
  • Road - W Snoqualmie River Rd NE
  • Ditch
  • Dry in summer
  • Mounted on 4x4

Installation Notes

Problems and Considerations (May 2020)

  • Sensor Height – mount > 15.8' above surface water in ditch.
    • Cantilever arm must be level and static.
    • Mount over center of ditch.
    • Could use tree behind existing post to get sensor up higher.
  • RSSI issues – mount antenna higher for better RSSI, site is furthest away from receiver, has connection problems.
  • Access issues – required height of sensor and position of ditch makes access difficult with a ladder.
    • Must be able to access transmitter on foot, or using a short ladder.