Revision as of 23:07, 23 May 2020

SVPA-26: W Snoqualmie River Rd NE at Blue Heron Golf Course

Attributes

  • Est. 2019
  • Road - W Snoqualmie River Rd NE
  • Ditch
  • Dry in summer
  • Mounted on 4x4

Installation Notes

Problems and Considerations (May 2020)

  • Sensor Height – mount > 15.8' above surface water in ditch.
    • Cantilever arm must be level and static.
    • Mount over center of ditch.
    • Could use tree behind existing post to get sensor up higher.
  • RSSI issues – mount antenna higher for better RSSI, site is furthest away from receiver, has connection problems.
  • Access issues – required height of sensor and position of ditch makes access difficult with a ladder.
    • Must be able to access transmitter on foot, or using a short ladder.