== SVPA-15: 124th St East at Local Roots Farm ==
+
==SVPA-15: 124th St East at Local Roots Farm==
 
{| class="wikitable" style="float:right; margin-left: 10px;"
 
{| class="wikitable" style="float:right; margin-left: 10px;"
! scope="row"| Status
+
! scope="row" |Status
| ACTIVE
+
|ACTIVE
 
|-
 
|-
! scope="row"| Upstream
+
! scope="row" |Upstream
| [[SVPA-17|SVPA-17 Goose & Gander]]
+
|[[SVPA-17|SVPA-17 Goose & Gander]]
 
|-
 
|-
! scope="row"| Downstream
+
! scope="row" |Downstream
| [[SVPA-15B|SVPA-15B 124th W]]  
+
|[[SVPA-15B|SVPA-15B 124th W]]
 
|}  
 
|}  
=== Attributes ===
+
===Attributes===
* Road - 124th St East - falling flood crosses here last
+
 
* Slough
+
*Est. 2019
* Senses concrete pad when water is low
+
*Road - 124th St East - falling flood crosses here last
* Mounted on 4x4 post with cement pad
+
*Slough
 +
*Senses concrete pad when water is low
 +
*Mounted on 4x4 post with cement pad
 +
 
 +
==Installation Notes==
 +
===Problems and Considerations (May 2020)===
  
== Installation Notes ==
 
=== Problems and Considerations (May 2020) ===
 
 
*Sensor Height – mount at same height or greater (15.04’).
 
*Sensor Height – mount at same height or greater (15.04’).
 
**Cantilever arm must be level and static.
 
**Cantilever arm must be level and static.
Line 32: Line 35:
 
**Problems with flood debris getting caught on post and being detected within the cone even after flood waters recede.
 
**Problems with flood debris getting caught on post and being detected within the cone even after flood waters recede.
  
== Links ==
+
==Links==
* [https://floodzilla.svpa.us/gage/SVPA-15 Floodzilla]
+
 
* [https://google.com/maps?q=47.7083725298009,-121.986264316517 Google Map]
+
*[https://floodzilla.svpa.us/gage/SVPA-15 Floodzilla]
 +
*[https://google.com/maps?q=47.7083725298009,-121.986264316517 Google Map]

Latest revision as of 18:19, 24 May 2020

SVPA-15: 124th St East at Local Roots Farm

Status ACTIVE
Upstream SVPA-17 Goose & Gander
Downstream SVPA-15B 124th W

Attributes

  • Est. 2019
  • Road - 124th St East - falling flood crosses here last
  • Slough
  • Senses concrete pad when water is low
  • Mounted on 4x4 post with cement pad

Installation Notes

Problems and Considerations (May 2020)

  • Sensor Height – mount at same height or greater (15.04’).
    • Cantilever arm must be level and static.
    • Mount out over center of ditch if possible.
  • RSSI issues – must be kept at same height for best RSSI.
  • Access issues – field adjacent to ditch is often saturated, access to site by foot.
    • Cannot reach transmitter to change batteries without taking the post down, shouldn't have to take post down to access transmitter.
    • Position of post adjacent to the ditch is awkward and unsafe when using a ladder to try and access sensor.
    • Could move the location closer to 124th St for better vehicle access.
  • Sensing Cone Issues – the cone of detection is very wide at the ground level.
    • Be sure sensor mounted out from the post by at least 24” (radius of cone at ground level).
    • Problems with flood debris getting caught on post and being detected within the cone even after flood waters recede.