Difference between revisions of "SVPA-37"

From floodzilla-wiki
Jump to navigation Jump to search
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
== SVPA-37: SE Fish Hatchery Rd at Snoqualmie Falls Golf Course ==
+
==SVPA-37: SE Fish Hatchery Rd at Snoqualmie Falls Golf Course==
* Downstream: [[SVPA-34]]
+
{| class="wikitable" style="float:right; margin-left: 10px;"
 +
! scope="row"| Status
 +
| ACTIVE
 +
|-
 +
! scope="row"| Upstream
 +
| [[USGS-38|USGS-38 Below the Falls]]
 +
|-
 +
! scope="row"| Downstream
 +
| [[SVPA-34|SVPA-34 The "T"]]
 +
|}
 +
 
 
Located north of the back parking lot.  
 
Located north of the back parking lot.  
=== Attributes ===
+
===Attributes===
* Est. 2019
+
 
* Dry when not flooding
+
*Est. 2019
* Mounted from 4x4 post
+
*Dry when not flooding
 +
*Mounted from 4x4 post
 +
 
 +
==Installation Notes==
 +
===Problems and Considerations (May 2020)===
  
== Installation Notes ==
 
=== Problems and Considerations (May 2020) ===
 
 
*Sensor Height – mount at current height or higher (> 11.31’).
 
*Sensor Height – mount at current height or higher (> 11.31’).
 
**Cantilever arm must be level and static.
 
**Cantilever arm must be level and static.
Line 29: Line 41:
 
**Sensing cone least 37.91” (diameter of cone at ground level).
 
**Sensing cone least 37.91” (diameter of cone at ground level).
  
=== Links ===
+
==Survey Notes==
* [https://floodzilla.svpa.us/gage/SVPA-37 Floodzilla]
+
===12/31/2020===
* [https://goo.gl/maps/cPvhp64qQ9THDZpz8 Google Map]
+
*[https://slack-files.com/T2ZFXMPC7-F01JVSH2DTP-9bc5e181bc Survey Notes]
 +
*[https://slack-files.com/T2ZFXMPC7-F01KNQHCHRN-b83a277cf6 Survey Data]
 +
===Links===
 +
 
 +
*[https://floodzilla.svpa.us/gage/SVPA-37 Floodzilla]
 +
*[https://goo.gl/maps/cPvhp64qQ9THDZpz8 Google Map]
 +
 
 +
[[Category:SVPA-Gage]]

Latest revision as of 22:08, 17 January 2021

SVPA-37: SE Fish Hatchery Rd at Snoqualmie Falls Golf Course

Status ACTIVE
Upstream USGS-38 Below the Falls
Downstream SVPA-34 The "T"

Located north of the back parking lot.

Attributes

  • Est. 2019
  • Dry when not flooding
  • Mounted from 4x4 post

Installation Notes

Problems and Considerations (May 2020)

  • Sensor Height – mount at current height or higher (> 11.31’).
    • Cantilever arm must be level and static.
    • Unsure of 60’ flood height at this location.
    • Currently sensing concrete wall, mount out over edge of concrete pad for best readings.
  • RSSI issues – Removed indoor receiver from this location. poor RSSI since this location is far from receiver.
    • Mount transmitter and antenna as high as possible (use existing telephone pole?)
    • Mount transmitter and sensor separately.
    • Use 30’ sensor with longer cable.
  • Access issues – location is immediately adjacent to parking lot, but height and position over ditch poses problem.
    • Transmitter is virtually inaccessible as it is now.
    • If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
    • Ladder will not fit in concrete pad below sensor – spread too wide.
  • Sensing Cone Issues – the cone of detection is very wide at the ground level.
    • Sensor should be mounted at minimum height requirements to minimize size of cone.
    • Vegetation (knotweed) will need to be maintained.
    • Sensing cone least 37.91” (diameter of cone at ground level).

Survey Notes

12/31/2020

Links