Difference between revisions of "Gage Testing"
(testing summary from 05-14-20) |
(error edits) |
||
| Line 27: | Line 27: | ||
Readings between 2:41pm and 2:54pm are not accurate because of the activity going on beneath the sensor during the increase in reading frequency change. | Readings between 2:41pm and 2:54pm are not accurate because of the activity going on beneath the sensor during the increase in reading frequency change. | ||
| − | 2:54pm = | + | 2:54pm = 100.87 |
| − | 2:55pm = | + | 2:55pm = 100.87 |
| − | 2:56pm = | + | 2:56pm = 100.87 |
| − | 2:57pm = | + | 2:57pm = 100.87 |
Lowered and raised sensor again | Lowered and raised sensor again | ||
Latest revision as of 15:06, 20 May 2020
05-14-20
Testing Flood Sensor Install at the "Lab" (Dean's)
Mounted 14' Senix sensor (ID 5101044, EUI 00-A8-0E) to Dean's prototype. Height of sensor = 87.6" (7.3') above concrete, Set height to 107.3' in Floodzilla (based on the concrete being 100')
Frequency of readings was set to every 15 minutes to start due to technical problems.
Filled 5-gal bucket with water and measured from face of sensor to water surface with tape (distance = 79.5" or 6.625')
2:05pm = 101.14'
Lowered sensor and raised it back up, then filled 5-gal bucket and measured from face of sensor to water surface with tape (distance = 82" or 6.83')
2:26pm = 101.13'
2:41pm = 101.11'
Determined that the width of the 5-gal bucket is too narrow for the sensing cone at the height the sensor was installed at (sensing cone ~22.11")
Switched 5-gal bucket with a 22.5" wide bucket and used a plumb line to ensure it was directly below sensor face.
Changed frequency of readings to every 60-seconds.
Filled bucket to brim with water and measured from face of sensor to water surface with tape (distance = 76.5" or 6.375')
Readings between 2:41pm and 2:54pm are not accurate because of the activity going on beneath the sensor during the increase in reading frequency change.
2:54pm = 100.87
2:55pm = 100.87
2:56pm = 100.87
2:57pm = 100.87
Lowered and raised sensor again
2:59pm = 100.88
3:00pm = 100.89
3:01pm = 100.89
3:02pm = 100.89
removed some water from bucket
3:03pm = 100.86