Difference between revisions of "SVPA-17"

From floodzilla-wiki
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
 
! scope="row"| Status
 
! scope="row"| Status
 
| ACTIVE
 
| ACTIVE
 +
|-
 +
! scope="row"| Upstream
 +
| [[SVPA-22|SVPA-22 Stossel Bridge]]
 
|-
 
|-
 
! scope="row"| Downstream
 
! scope="row"| Downstream
| [[USGS-22|USGS-22 Carnation]]
 
|-
 
! scope="row"| Upstream
 
 
| [[SVPA-15|SVPA-15 124th East]]  
 
| [[SVPA-15|SVPA-15 124th East]]  
 
|}  
 
|}  

Latest revision as of 17:41, 24 May 2020

SVPA-17: NE 100th St at Goose & Gander Farm

Status ACTIVE
Upstream SVPA-22 Stossel Bridge
Downstream SVPA-15 124th East

Attributes

  • Road - NE 100th St
  • Est. 2019
  • Farm field
  • Dry when not flooding
  • Mounted on 4x4 post

Installation Notes

Problems and Considerations: (May 2020)

  • Sensor Height – mount at least 12.69’ above concrete pad.
    • Cantilever arm must be level and static.
    • This site could use a 14’ sensor if it is repaired.
  • Access issues – location is immediately adjacent to farm access road, but may not be useable to access.  
    • Will need ladder or some way to access transmitter for battery changes, maintenance.
  • Sensing Cone Issues – the cone of detection will be wider since the sensor will be higher than is currently.
    • Sensor should be mounted out (> 21”) away from post (radius of cone).