Difference between revisions of "SVPA-26"

From floodzilla-wiki
Jump to navigation Jump to search
Line 1: Line 1:
 
==SVPA-26: W Snoqualmie River Rd NE at Blue Heron Golf Course==
 
==SVPA-26: W Snoqualmie River Rd NE at Blue Heron Golf Course==
 +
 +
* Upstream: [[SVPA-33]] Keller Dairy
 +
* Downstream: [[USGS-22]] Carnation
 +
 
===Attributes===
 
===Attributes===
  

Revision as of 23:06, 23 May 2020

SVPA-26: W Snoqualmie River Rd NE at Blue Heron Golf Course

Attributes

  • Road - W Snoqualmie River Rd NE
  • Ditch
  • Dry in summer

Installation Notes

Problems and Considerations (May 2020)

  • Sensor Height – mount > 15.8' above surface water in ditch.
    • Cantilever arm must be level and static.
    • Mount over center of ditch.
    • Could use tree behind existing post to get sensor up higher.
  • RSSI issues – mount antenna higher for better RSSI, site is furthest away from receiver, has connection problems.
  • Access issues – required height of sensor and position of ditch makes access difficult with a ladder.
    • Must be able to access transmitter on foot, or using a short ladder.

Links