Difference between revisions of "SVPA-37"
Jump to navigation
Jump to search
GearyEppley (talk | contribs) |
GearyEppley (talk | contribs) |
||
| Line 1: | Line 1: | ||
| − | == SVPA-37: SE Fish Hatchery Rd at Snoqualmie Falls Golf Course == | + | ==SVPA-37: SE Fish Hatchery Rd at Snoqualmie Falls Golf Course== |
| − | * Downstream: [[SVPA-34]] | + | |
| + | *Downstream: [[SVPA-34]] | ||
| + | |||
Located north of the back parking lot. | Located north of the back parking lot. | ||
| − | === Attributes === | + | ===Attributes=== |
| − | * Est. 2019 | + | |
| − | * Dry when not flooding | + | *Est. 2019 |
| − | * Mounted from 4x4 post | + | *Dry when not flooding |
| + | *Mounted from 4x4 post | ||
| + | |||
| + | ==Installation Notes== | ||
| + | ===Problems and Considerations (May 2020)=== | ||
| − | |||
| − | |||
*Sensor Height – mount at current height or higher (> 11.31’). | *Sensor Height – mount at current height or higher (> 11.31’). | ||
**Cantilever arm must be level and static. | **Cantilever arm must be level and static. | ||
| Line 29: | Line 33: | ||
**Sensing cone least 37.91” (diameter of cone at ground level). | **Sensing cone least 37.91” (diameter of cone at ground level). | ||
| − | === Links === | + | ===Links=== |
| − | * [https://floodzilla.svpa.us/gage/SVPA-37 Floodzilla] | + | |
| − | * [https://goo.gl/maps/cPvhp64qQ9THDZpz8 Google Map] | + | *[https://floodzilla.svpa.us/gage/SVPA-37 Floodzilla] |
| + | *[https://goo.gl/maps/cPvhp64qQ9THDZpz8 Google Map] | ||
| + | |||
| + | [[Category:SVPA-Gage]] | ||
Revision as of 22:58, 23 May 2020
Contents
SVPA-37: SE Fish Hatchery Rd at Snoqualmie Falls Golf Course
- Downstream: SVPA-34
Located north of the back parking lot.
Attributes
- Est. 2019
- Dry when not flooding
- Mounted from 4x4 post
Installation Notes
Problems and Considerations (May 2020)
- Sensor Height – mount at current height or higher (> 11.31’).
- Cantilever arm must be level and static.
- Unsure of 60’ flood height at this location.
- Currently sensing concrete wall, mount out over edge of concrete pad for best readings.
- RSSI issues – Removed indoor receiver from this location. poor RSSI since this location is far from receiver.
- Mount transmitter and antenna as high as possible (use existing telephone pole?)
- Mount transmitter and sensor separately.
- Use 30’ sensor with longer cable.
- Access issues – location is immediately adjacent to parking lot, but height and position over ditch poses problem.
- Transmitter is virtually inaccessible as it is now.
- If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
- Ladder will not fit in concrete pad below sensor – spread too wide.
- Sensing Cone Issues – the cone of detection is very wide at the ground level.
- Sensor should be mounted at minimum height requirements to minimize size of cone.
- Vegetation (knotweed) will need to be maintained.
- Sensing cone least 37.91” (diameter of cone at ground level).