| − | ''' | + | <u>'''Gage Installations - Location Specifications and Considerations for Upgrades'''</u> |
<br /> | <br /> | ||
| − | |||
| − | |||
| − | '' | + | '''FOR EACH LOCATION KEEP IN MIND:''' |
| − | |||
| − | |||
| − | |||
| − | '' | + | '''Accessibility''' |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | + | * Ease of access to transmitter box to change batteries or remove for troubleshooting or repair. | |
| − | |||
| − | |||
| − | + | '''Theft and Tampering''' | |
| − | + | * This hasn’t been a significant problem, but something to keep in mind. | |
| − | + | '''Data Reliability''' | |
| − | + | * Sensor must be at same exact height in exact same position each time it is raised and lowered. | |
| − | + | * Sensor must be perpendicular to ground. | |
| − | + | * If on a cantilevered arm that raises and lowers, the arm must be level and static when raised. | |
| − | + | '''Flood Height''' | |
| − | + | * Sensors must be mounted above 60’ flood level. | |
| − | + | * The USGS Carnation gage recorded 60’ flood was ~4.5’ higher than the Oct 22, 2019 flood. | |
| − | + | * See '''Table 1.''' for sensor mounting height requirements. | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
Table 1. Sensor Height Requirements for Maximum Flood Levels | Table 1. Sensor Height Requirements for Maximum Flood Levels | ||
{| class="wikitable" | {| class="wikitable" | ||
| − | |''' | + | |'''Gage Location''' |
|'''Current Sensor Height (ft ASL)''' | |'''Current Sensor Height (ft ASL)''' | ||
|'''Oct 22nd Flood Crest (ft ASL)''' | |'''Oct 22nd Flood Crest (ft ASL)''' | ||
| − | |'''Estimated 60' Flood Crest (ft ASL)''' | + | |'''Estimated 60' Flood Crest (ft ASL)''' |
|'''Distance of 60' Flood from Sensor (ft)''' | |'''Distance of 60' Flood from Sensor (ft)''' | ||
|'''Current Sensor Height (ft above ground)''' | |'''Current Sensor Height (ft above ground)''' | ||
|'''New Sensor Height Requirements (ft above ground)''' | |'''New Sensor Height Requirements (ft above ground)''' | ||
|- | |- | ||
| − | | | + | |SE Fish Hatchery Road at Snoqualmie Falls Golf Course |
|99.06 | |99.06 | ||
| − | | | + | |unknown - not running during flood |
| | | | ||
| | | | ||
| Line 65: | Line 46: | ||
|>11.31 | |>11.31 | ||
|- | |- | ||
| − | | | + | |W Snoqualmie River Rd SE at the “T” |
|81.69 | |81.69 | ||
|80.47 | |80.47 | ||
| Line 73: | Line 54: | ||
|12.48 | |12.48 | ||
|- | |- | ||
| − | |Keller Dairy | + | |Snoqualmie River at Keller Dairy |
|90.68 | |90.68 | ||
|85.84 | |85.84 | ||
| Line 81: | Line 62: | ||
|20 | |20 | ||
|- | |- | ||
| − | |Blue Heron Golf Course | + | |W Snoqualmie River Rd NE at the Blue Heron Golf Course |
|74.32 | |74.32 | ||
| − | |73.46 | + | |73.46 (max pre-crest, sensor taken down due to flood levels approaching sensor) |
|77.96 | |77.96 | ||
|<nowiki>-3.64</nowiki> | |<nowiki>-3.64</nowiki> | ||
|11.3 | |11.3 | ||
| − | |15.8 | + | |>15.8 |
|- | |- | ||
| − | |Tolt Bridge | + | |Snoqualmie River at the Tolt Bridge |
| − | | | + | |not installed |
|unknown | |unknown | ||
|unknown | |unknown | ||
| − | | | + | |n/a |
| − | | | + | |n/a |
| − | | | + | |height of bridge guard rail adequate |
|- | |- | ||
| − | |Stossel Bridge | + | |Snoqualmie River at Stossel Bridge |
| − | | | + | |not installed |
|57.96 | |57.96 | ||
|62.46 | |62.46 | ||
| − | | | + | |n/a |
| − | | | + | |n/a |
| − | | | + | |height of bridge guard rail adequate |
|- | |- | ||
| − | |Goose and Gander | + | |NE 100<sup>th</sup> St at Goose and Gander Farm |
|54.24 | |54.24 | ||
|53.81 | |53.81 | ||
| Line 113: | Line 94: | ||
|12.69 | |12.69 | ||
|- | |- | ||
| − | | | + | |24<sup>th</sup> St East at Local Roots Farm |
|55.45 | |55.45 | ||
|46.96 | |46.96 | ||
| Line 121: | Line 102: | ||
|15.04 | |15.04 | ||
|- | |- | ||
| − | | | + | |124<sup>th</sup> St West |
| − | | | + | |not installed |
| − | | | + | |estimate based on photos and 124th E |
| − | | | + | |unknown |
| − | | | + | |n/a |
| − | | | + | |n/a |
|TBD | |TBD | ||
|- | |- | ||
| − | |Wild Canary Farm | + | |NE 138<sup>th</sup> St at Wild Canary Farm |
|47.9 | |47.9 | ||
|45.26 | |45.26 | ||
| Line 138: | Line 119: | ||
|} | |} | ||
| + | '''Antennas''' | ||
| − | + | * Must be mounted directly on transmitter box and cannot be extended. | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | + | '''Transmitters''' | |
| − | + | * Mount transmitter as high as possible to improve line of sight and RSSI. | |
| + | * Must be easily accessible from the ground or using a short ladder. | ||
| + | * Can be mounted separate from sensor. | ||
| + | * Cannot become submerged during flooding. | ||
| − | + | '''Sensors''' | |
| − | + | * Can be mounted separate from transmitter. | |
| + | * Cannot be mounted higher than the range of sensor (30’ sensor: 30’, 14’ sensor: 14’) | ||
| + | * Come with 6’ cable - can be cut. | ||
| + | * Can be ordered with longer cables (15 – 200'). | ||
| + | * Will not give accurate readings if flood waters are within 10” of the sensor face. | ||
| + | * Can be submerged during flooding BUT, will not give accurate readings. | ||
| + | * Must be mounted directly over center of ditch/concrete pad. | ||
| − | + | '''Sensor Cone''' | |
| − | + | * Emits an ultrasonic pulse with a 15° sensing cone. | |
| − | + | * The higher the sensor, the larger the diameter of the sensing cone at the ground/water surface. | |
| − | + | * Be sure the sensor is extended far enough from the mounting pole to not sense it. | |
| − | + | * See '''Table 2.''' For cone diameters | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
Table 2. Ultrasonic Cone Diameters at Varying Heights | Table 2. Ultrasonic Cone Diameters at Varying Heights | ||
| Line 307: | Line 275: | ||
| + | '''GAGE LOCATIONS:''' | ||
| − | '''1. W Snoqualmie River Rd NE at the Blue Heron Golf Course''' | + | '''1. W Snoqualmie River Rd NE at the Blue Heron Golf Course''' |
| − | '''Problems and Considerations:''' | + | '''Problems and Considerations:''' |
| − | + | * Sensor Height – mount > 15.8' above surface water in ditch. | |
| + | ** Cantilever arm must be level and static. | ||
| + | ** Mount over center of ditch. | ||
| + | ** Could use tree behind existing post to get sensor up higher. | ||
| + | * RSSI issues – mount antenna higher for better RSSI, site is furthest away from receiver, has connection problems. | ||
| + | * Access issues – required height of sensor and position of ditch makes access difficult with a ladder. | ||
| + | ** Must be able to access transmitter on foot, or using a short ladder. | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
'''2. 124<sup>th</sup> St East at Local Roots Farm''' | '''2. 124<sup>th</sup> St East at Local Roots Farm''' | ||
| − | '''Problems and Considerations:''' | + | '''Problems and Considerations:''' |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | + | * Sensor Height – mount at same height or greater (15.04’). | |
| + | ** Cantilever arm must be level and static. | ||
| + | ** Mount out over center of ditch if possible. | ||
| − | + | * RSSI issues – must be kept at same height for best RSSI. | |
| + | * Access issues – field adjacent to ditch is often saturated, access to site by foot. | ||
| + | ** Cannot reach transmitter to change batteries without taking the post down, shouldn't have to take post down to access transmitter. | ||
| + | ** Position of post adjacent to the ditch is awkward and unsafe when using a ladder to try and access sensor. | ||
| + | ** Could move the location closer to 124<sup>th</sup> St for better vehicle access. | ||
| − | + | * Sensing Cone Issues – the cone of detection is very wide at the ground level. | |
| + | ** Be sure sensor mounted out from the post by at least 24” (radius of cone at ground level). | ||
| + | ** Problems with flood debris getting caught on post and being detected within the cone even after flood waters recede. | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
'''3. NE 138<sup>th</sup> St at Wild Canary Farm''' | '''3. NE 138<sup>th</sup> St at Wild Canary Farm''' | ||
| − | '''Problems and Considerations:''' | + | '''Problems and Considerations:''' |
| − | + | * Sensor Height – mount at least 14.5’ above bottom of ditch (must be > 2’ higher than current) | |
| + | ** Mount out over center of ditch. | ||
| + | ** Cantilever arm must be level and static. | ||
| + | ** Sensor should be moved from NNW to more of a NW orientation to be directly over the ditch to get the best possible readings. | ||
| − | + | * RSSI issues – poor RSSI since this location is farthest from receiver and is in a topographic hole. | |
| + | ** Mount transmitter and antenna as high as possible (use existing telephone pole?) | ||
| + | ** Mount transmitter and sensor separately. | ||
| + | ** Use 30’ sensor with longer cable. | ||
| − | + | * Access issues – location is immediately adjacent to gravel road, but height poses problem. | |
| + | ** If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance. | ||
| − | + | * Sensing Cone Issues – the cone of detection is very wide at the ground level. | |
| + | ** Sensor should be mounted at minimum height requirements to minimize size of cone. | ||
| + | ** Vegetation will need to be cut back extensively along ditch edges. | ||
| + | ** Sensing cone least 44.23” (diameter of cone at ground level). | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
'''4. W Snoqualmie River Rd SE at the “T”''' | '''4. W Snoqualmie River Rd SE at the “T”''' | ||
| − | |||
'''Problems and Considerations:''' | '''Problems and Considerations:''' | ||
| − | + | * Sensor Height – mount at 12.48’ above bottom of ditch. | |
| + | ** Currently the only site using a 14’ sensor – do not mount higher than 14’. | ||
| − | + | * Access issues – location is immediately adjacent to road but will be raised up higher. | |
| + | ** This is the lowest part of the road, so it should be installed in the same location. | ||
| + | ** Theft worries? | ||
| − | + | * Sensing Cone Issues – the cone of detection will be wider with the new height. | |
| − | + | * Be sure sensor mounted out from the post by at least 20.5” (radius of cone at ground level). | |
| − | + | * Be sure road edge is not within cone. | |
| − | + | * May need to install post back from ditch. | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| Line 402: | Line 353: | ||
'''Problems and Considerations:''' | '''Problems and Considerations:''' | ||
| − | + | * Sensor Height – mount at current height or higher (> 11.31’). | |
| − | + | ** Cantilever arm must be level and static. | |
| − | + | ** Unsure of 60’ flood height at this location. | |
| − | + | ** Currently sensing concrete wall, mount out over edge of concrete pad for best readings. | |
| − | |||
| − | + | * RSSI issues – Removed indoor receiver from this location. poor RSSI since this location is far from receiver. | |
| + | ** Mount transmitter and antenna as high as possible (use existing telephone pole?) | ||
| + | ** Mount transmitter and sensor separately. | ||
| + | ** Use 30’ sensor with longer cable. | ||
| − | + | * Access issues – location is immediately adjacent to parking lot, but height and position over ditch poses problem. | |
| + | ** Transmitter is virtually inaccessible as it is now. | ||
| + | ** If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance. | ||
| + | ** Ladder will not fit in concrete pad below sensor – spread too wide. | ||
| − | + | * Sensing Cone Issues – the cone of detection is very wide at the ground level. | |
| − | + | ** Sensor should be mounted at minimum height requirements to minimize size of cone. | |
| − | + | ** Vegetation (knotweed) will need to be maintained. | |
| − | + | ** Sensing cone least 37.91” (diameter of cone at ground level). | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
'''6. Snoqualmie River at Keller Dairy''' | '''6. Snoqualmie River at Keller Dairy''' | ||
| − | |||
'''Problems and Considerations:''' | '''Problems and Considerations:''' | ||
| − | + | * Sensor Height – mount at current height (20’). | |
| − | + | ** Cantilever arm must be level and static. | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | + | * RSSI issues – receiver is nearby, but leaf cover may be blocking line of sight. | |
| + | ** Could try to get antenna out over river further or up higher. | ||
| + | ** Could mount transmitter and sensor separately. | ||
| − | + | * Safety Issues – location has a steep (~10’) drop off into the river. | |
| + | ** Design must take into account river safety and ease of access of transmitter. | ||
| − | + | * Access issues – location is immediately adjacent to road, but in a precarious spot at edge of bank. | |
| + | ** If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance. | ||
| − | + | * Sensing Cone Issues – the cone of detection is very wide at water surface. | |
| + | ** Any interfering branches may need to be removed. | ||
| + | ** Sensor should be mounted out over the river as far as it is now or farther. | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
'''7. NE 100<sup>th</sup> St at Goose and Gander Farm''' | '''7. NE 100<sup>th</sup> St at Goose and Gander Farm''' | ||
| Line 470: | Line 400: | ||
'''Problems and Considerations:''' | '''Problems and Considerations:''' | ||
| − | + | * Sensor Height – mount at least 12.69’ above concrete pad. | |
| − | + | ** Cantilever arm must be level and static. | |
| − | + | ** This site could use a 14’ sensor if it is repaired. | |
| − | |||
| − | |||
| − | + | * Access issues – location is immediately adjacent to farm access road, but may not be useable to access. | |
| + | ** Will need ladder or some way to access transmitter for battery changes, maintenance. | ||
| − | + | * Sensing Cone Issues – the cone of detection will be wider since the sensor will be higher than is currently. | |
| + | ** Sensor should be mounted out (> 21”) away from post (radius of cone). | ||
| − | |||
| − | |||
| − | |||
'''8. 124<sup>th</sup> St West – Location TBD (47.709092, -122.002502)''' | '''8. 124<sup>th</sup> St West – Location TBD (47.709092, -122.002502)''' | ||
| Line 488: | Line 415: | ||
'''Considerations:''' | '''Considerations:''' | ||
| − | + | * Needs to be constructed in the KC right of way, over the ditch. | |
| − | + | * Find the low spot in the road using survey data for better placement. | |
| − | + | * Height TBD based on estimated flood height here. | |
| − | + | * Will need a design that is easy to access without a ladder since there is no parking to bring a ladder and it’s right next to a busy street. | |
| − | |||
| − | |||
| − | |||
Revision as of 22:46, 7 May 2020
Gage Installations - Location Specifications and Considerations for Upgrades
FOR EACH LOCATION KEEP IN MIND:
Accessibility
- Ease of access to transmitter box to change batteries or remove for troubleshooting or repair.
Theft and Tampering
- This hasn’t been a significant problem, but something to keep in mind.
Data Reliability
- Sensor must be at same exact height in exact same position each time it is raised and lowered.
- Sensor must be perpendicular to ground.
- If on a cantilevered arm that raises and lowers, the arm must be level and static when raised.
Flood Height
- Sensors must be mounted above 60’ flood level.
- The USGS Carnation gage recorded 60’ flood was ~4.5’ higher than the Oct 22, 2019 flood.
- See Table 1. for sensor mounting height requirements.
Table 1. Sensor Height Requirements for Maximum Flood Levels
| Gage Location | Current Sensor Height (ft ASL) | Oct 22nd Flood Crest (ft ASL) | Estimated 60' Flood Crest (ft ASL) | Distance of 60' Flood from Sensor (ft) | Current Sensor Height (ft above ground) | New Sensor Height Requirements (ft above ground) |
| SE Fish Hatchery Road at Snoqualmie Falls Golf Course | 99.06 | unknown - not running during flood | 11.31 | >11.31 | ||
| W Snoqualmie River Rd SE at the “T” | 81.69 | 80.47 | 84.97 | -3.28 | 7.98 | 12.48 |
| Snoqualmie River at Keller Dairy | 90.68 | 85.84 | 90.34 | 0.34 | 20 | 20 |
| W Snoqualmie River Rd NE at the Blue Heron Golf Course | 74.32 | 73.46 (max pre-crest, sensor taken down due to flood levels approaching sensor) | 77.96 | -3.64 | 11.3 | >15.8 |
| Snoqualmie River at the Tolt Bridge | not installed | unknown | unknown | n/a | n/a | height of bridge guard rail adequate |
| Snoqualmie River at Stossel Bridge | not installed | 57.96 | 62.46 | n/a | n/a | height of bridge guard rail adequate |
| NE 100th St at Goose and Gander Farm | 54.24 | 53.81 | 58.31 | -4.07 | 8.19 | 12.69 |
| 24th St East at Local Roots Farm | 55.45 | 46.96 | 51.46 | 3.99 | 15.04 | 15.04 |
| 124th St West | not installed | estimate based on photos and 124th E | unknown | n/a | n/a | TBD |
| NE 138th St at Wild Canary Farm | 47.9 | 45.26 | 49.76 | -1.86 | 12.3 | 14.5 |
Antennas
- Must be mounted directly on transmitter box and cannot be extended.
Transmitters
- Mount transmitter as high as possible to improve line of sight and RSSI.
- Must be easily accessible from the ground or using a short ladder.
- Can be mounted separate from sensor.
- Cannot become submerged during flooding.
Sensors
- Can be mounted separate from transmitter.
- Cannot be mounted higher than the range of sensor (30’ sensor: 30’, 14’ sensor: 14’)
- Come with 6’ cable - can be cut.
- Can be ordered with longer cables (15 – 200').
- Will not give accurate readings if flood waters are within 10” of the sensor face.
- Can be submerged during flooding BUT, will not give accurate readings.
- Must be mounted directly over center of ditch/concrete pad.
Sensor Cone
- Emits an ultrasonic pulse with a 15° sensing cone.
- The higher the sensor, the larger the diameter of the sensing cone at the ground/water surface.
- Be sure the sensor is extended far enough from the mounting pole to not sense it.
- See Table 2. For cone diameters
Table 2. Ultrasonic Cone Diameters at Varying Heights
| Distance from Sensor (ft) | Diameter of Cone (in) | Diameter of Cone (ft) |
| 1 | 3.15 | 0.26 |
| 2 | 6.32 | 0.53 |
| 3 | 9.47 | 0.79 |
| 4 | 12.64 | 1.05 |
| 5 | 15.79 | 1.32 |
| 6 | 18.96 | 1.58 |
| 7 | 22.11 | 1.84 |
| 8 | 25.27 | 2.11 |
| 9 | 28.43 | 2.37 |
| 10 | 31.59 | 2.63 |
| 11 | 34.75 | 2.90 |
| 12 | 37.91 | 3.16 |
| 13 | 41.07 | 3.42 |
| 14 | 44.23 | 3.69 |
| 15 | 47.39 | 3.95 |
| 16 | 50.55 | 4.21 |
| 17 | 53.71 | 4.48 |
| 18 | 56.87 | 4.74 |
| 19 | 60.02 | 5.00 |
| 20 | 63.18 | 5.27 |
| 21 | 66.34 | 5.53 |
| 22 | 69.50 | 5.79 |
| 23 | 72.66 | 6.06 |
| 24 | 75.82 | 6.32 |
| 25 | 78.98 | 6.58 |
| 26 | 82.14 | 6.84 |
| 27 | 85.30 | 7.11 |
| 28 | 88.46 | 7.37 |
| 29 | 91.62 | 7.63 |
| 30 | 94.78 | 7.90 |
GAGE LOCATIONS:
1. W Snoqualmie River Rd NE at the Blue Heron Golf Course
Problems and Considerations:
- Sensor Height – mount > 15.8' above surface water in ditch.
- Cantilever arm must be level and static.
- Mount over center of ditch.
- Could use tree behind existing post to get sensor up higher.
- RSSI issues – mount antenna higher for better RSSI, site is furthest away from receiver, has connection problems.
- Access issues – required height of sensor and position of ditch makes access difficult with a ladder.
- Must be able to access transmitter on foot, or using a short ladder.
2. 124th St East at Local Roots Farm
Problems and Considerations:
- Sensor Height – mount at same height or greater (15.04’).
- Cantilever arm must be level and static.
- Mount out over center of ditch if possible.
- RSSI issues – must be kept at same height for best RSSI.
- Access issues – field adjacent to ditch is often saturated, access to site by foot.
- Cannot reach transmitter to change batteries without taking the post down, shouldn't have to take post down to access transmitter.
- Position of post adjacent to the ditch is awkward and unsafe when using a ladder to try and access sensor.
- Could move the location closer to 124th St for better vehicle access.
- Sensing Cone Issues – the cone of detection is very wide at the ground level.
- Be sure sensor mounted out from the post by at least 24” (radius of cone at ground level).
- Problems with flood debris getting caught on post and being detected within the cone even after flood waters recede.
3. NE 138th St at Wild Canary Farm
Problems and Considerations:
- Sensor Height – mount at least 14.5’ above bottom of ditch (must be > 2’ higher than current)
- Mount out over center of ditch.
- Cantilever arm must be level and static.
- Sensor should be moved from NNW to more of a NW orientation to be directly over the ditch to get the best possible readings.
- RSSI issues – poor RSSI since this location is farthest from receiver and is in a topographic hole.
- Mount transmitter and antenna as high as possible (use existing telephone pole?)
- Mount transmitter and sensor separately.
- Use 30’ sensor with longer cable.
- Access issues – location is immediately adjacent to gravel road, but height poses problem.
- If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
- Sensing Cone Issues – the cone of detection is very wide at the ground level.
- Sensor should be mounted at minimum height requirements to minimize size of cone.
- Vegetation will need to be cut back extensively along ditch edges.
- Sensing cone least 44.23” (diameter of cone at ground level).
4. W Snoqualmie River Rd SE at the “T”
Problems and Considerations:
- Sensor Height – mount at 12.48’ above bottom of ditch.
- Currently the only site using a 14’ sensor – do not mount higher than 14’.
- Access issues – location is immediately adjacent to road but will be raised up higher.
- This is the lowest part of the road, so it should be installed in the same location.
- Theft worries?
- Sensing Cone Issues – the cone of detection will be wider with the new height.
- Be sure sensor mounted out from the post by at least 20.5” (radius of cone at ground level).
- Be sure road edge is not within cone.
- May need to install post back from ditch.
5. SE Fish Hatchery Road at Snoqualmie Falls Golf Course
Problems and Considerations:
- Sensor Height – mount at current height or higher (> 11.31’).
- Cantilever arm must be level and static.
- Unsure of 60’ flood height at this location.
- Currently sensing concrete wall, mount out over edge of concrete pad for best readings.
- RSSI issues – Removed indoor receiver from this location. poor RSSI since this location is far from receiver.
- Mount transmitter and antenna as high as possible (use existing telephone pole?)
- Mount transmitter and sensor separately.
- Use 30’ sensor with longer cable.
- Access issues – location is immediately adjacent to parking lot, but height and position over ditch poses problem.
- Transmitter is virtually inaccessible as it is now.
- If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
- Ladder will not fit in concrete pad below sensor – spread too wide.
- Sensing Cone Issues – the cone of detection is very wide at the ground level.
- Sensor should be mounted at minimum height requirements to minimize size of cone.
- Vegetation (knotweed) will need to be maintained.
- Sensing cone least 37.91” (diameter of cone at ground level).
6. Snoqualmie River at Keller Dairy
Problems and Considerations:
- Sensor Height – mount at current height (20’).
- Cantilever arm must be level and static.
- RSSI issues – receiver is nearby, but leaf cover may be blocking line of sight.
- Could try to get antenna out over river further or up higher.
- Could mount transmitter and sensor separately.
- Safety Issues – location has a steep (~10’) drop off into the river.
- Design must take into account river safety and ease of access of transmitter.
- Access issues – location is immediately adjacent to road, but in a precarious spot at edge of bank.
- If transmitter is mounted separate from sensor, both will need to still be accessible for battery changes, maintenance.
- Sensing Cone Issues – the cone of detection is very wide at water surface.
- Any interfering branches may need to be removed.
- Sensor should be mounted out over the river as far as it is now or farther.
7. NE 100th St at Goose and Gander Farm
Problems and Considerations:
- Sensor Height – mount at least 12.69’ above concrete pad.
- Cantilever arm must be level and static.
- This site could use a 14’ sensor if it is repaired.
- Access issues – location is immediately adjacent to farm access road, but may not be useable to access.
- Will need ladder or some way to access transmitter for battery changes, maintenance.
- Sensing Cone Issues – the cone of detection will be wider since the sensor will be higher than is currently.
- Sensor should be mounted out (> 21”) away from post (radius of cone).
8. 124th St West – Location TBD (47.709092, -122.002502)
Considerations:
- Needs to be constructed in the KC right of way, over the ditch.
- Find the low spot in the road using survey data for better placement.
- Height TBD based on estimated flood height here.
- Will need a design that is easy to access without a ladder since there is no parking to bring a ladder and it’s right next to a busy street.
BRIDGE INSTALLS
9. Stossel Bridge
10. Tolt Bridge